Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CF0061 Communication Link Fault Among The Controller And Management Modules

0xF00CF0061 Communication Link Fault Among The Controller And Management Modules

Description

The controller and management modules fail to communicate with each other properly because the communication links among the controller and management modules are faulty.

Applicable Model

Applicable to OceanStor Dorado6000 V3/Dorado18000 V3 storage systems.

Attribute

ID

Event Level

Automatically Cleared

0xF00CF0061

Major

Yes

Impact on the System

The system hardware cannot be monitored.

Possible Causes

  • The management module is faulty.
  • The controller is faulty.
  • The backplane is faulty.

Procedure

  1. Replace the management module. If the alarm persists=> Step2.
  2. Replace the controller. If the alarm persists=> Step3.
  3. Collect related information and contact technical support engineers to replace the enclosure.