Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CF0073 The Controller Power-on Times Out

0xF00CF0073 The Controller Power-on Times Out

Description

The controller power-on times out.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00CF0073

Critical

Yes

Impact on the System

  • The controller power-on times out. System reliability decreases.
  • With the write protection function being enabled (by default) when an engine works with a single controller, if the controller that fails to be initiated cannot return to normal within the specified period, the write function of services on the engine where the faulty node resides is disabled and the read/write performance is reduced.

Possible Causes

The controller has internal errors.

Procedure

  1. Collect the log information and contact technical support engineers to rectify the fault. If the fault cannot be rectified immediately=> Step2.
  2. The write policy of the system will become write through after a while, decreasing read/write performance. If you want to restore system performance, enter the developer view of the CLI and run the "change system write_through_policy write_through_switch=Disable" command to disable write through of the controller. However, if the controller malfunctions after the function is disabled, data may be lost, affecting system reliability.