No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00CF0078 The Monitor Link Between The Controller And The Enclosure Is Faulty

0xF00CF0078 The Monitor Link Between The Controller And The Enclosure Is Faulty

Description

The monitor link between the controller and the enclosure is faulty.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00CF0078

Major

Yes

Impact on the System

  • System hardware devices (power supplies, BBU modules, enclosure or fans) may not be monitored.
  • Storage system reliability degrades.

Possible Causes

  • I2C component on the controller is faulty.
  • The communication link between the controller and the enclosure breaks down.

Procedure

  1. Replace the controller. If the alarm persists=> Step2.
  2. Replace the controller enclosure. If the alarm persists=> Step3.
  3. Collect log information and contact technical support engineers. Method 1: On DeviceManager, choose "Settings" > "Export Data" to export log information. Method 2: On CLI, run the "export event" command to export log information.
Translation
Download
Updated: 2018-10-19

Document ID: EDOC1000141827

Views: 84177

Downloads: 166

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next