No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00D00017 Failed To Synchronize The Firmware Version Of An Expansion Module

0xF00D00017 Failed To Synchronize The Firmware Version Of An Expansion Module

Description

Failed to synchronize the firmware version of an expansion module.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00D00017

Major

Yes

Impact on the System

Ports on the expansion module are isolated.

Possible Causes

  • The cable is faulty or not securely connected.
  • The interface module is removed or faulty.
  • The expansion module is faulty.

Procedure

  1. Check cable connections.

    1. If the cable is removed, reinsert it. If the alarm persists=> 1.2.
    2. Replace the cable. If the alarm persists=> Step2.

  2. Check interface modules.

    1. If an interface module is removed, reinsert it. If the alarm persists=> 2.2.
    2. If an interface module is damaged, replace it. If the alarm persists=> Step3.
    3. If no interface module is removed or damaged=> Step3.

  3. Replace the expansion module. If the alarm persists=> Step4.
  4. Collect related information and contact technical support engineers.
Translation
Download
Updated: 2018-10-19

Document ID: EDOC1000141827

Views: 94222

Downloads: 178

Average rating:
This Document Applies to these Products

Related Version

Related Documents

Share
Previous Next