Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00E00039 Number Of Links Between Storage Arrays Reaches The System Limit

0xF00E00039 Number Of Links Between Storage Arrays Reaches The System Limit

Description

The number of links between storage arrays exceeds the system limit.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00E00039

Warning

Yes

Impact on the System

N/A

Possible Causes

Switch zones are not correctly assigned, or some links are not used.

Procedure

  1. After switch zones are assigned, check whether the number of available links is smaller than the system limit.

    1. If no, assign switch zones correctly. If the alarm persists=> Step2.
    2. If yes=> Step2.

  2. Check whether some links in the system are not used.

    1. If yes, remove cables of the unused links connected to the local storage array. If the alarm persists on the remote array, remove cables of the unused links connected to the remote storage array. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Collect all related information and contact technical support engineers.