Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF00E0003A Replication Link Is Degraded

0xF00E0003A Replication Link Is Degraded

Description

The replication link between the local and remote devices is degraded.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF00E0003A

Warning

No

Impact on the System

  • When HyperMetro or synchronous remote replication is configured between storage arrays, degrading the replication link may degrade system performance and reliability, or even affect host services.
  • When asynchronous remote replication is configured between storage arrays, degrading the replication link may affect the synchronization speed.

Possible Causes

  • Packet loss or bit errors occur on the local or remote port.
  • Packet loss, disorder, or bit errors occur on the switch.
  • The service load on the local or remote array is too heavy.

Procedure

  1. Check whether bit errors and packet loss occur on the local and remote replication link ports.

    1. If yes, replace the optical module. If the alarm persists=> 1.2.
    2. Replace the cable. If the alarm persists=> 1.3.
    3. Replace the interface module. If the alarm persists=> Step2.
    4. If no bit error or packet loss occurs=> Step2.

  2. Check whether the switch related to the replication link is normal.

    1. If packet loss, disorder, or bit errors occur on the switch, rectify the fault. If the alarm persists=> Step3.
    2. If the switch is normal=> Step3.

  3. Check whether the service load on the local and remote arrays is too heavy.

    1. If yes, contact technical support engineers for capacity expansion and service optimization.
    2. If no, collect related information and contact technical support engineers.