This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF010A0059 Hot Spare Capacity Of The Disk Domain Is Insufficient

0xF010A0059 Hot Spare Capacity Of The Disk Domain Is Insufficient

Description

The hot spare space for a disk domain is insufficient.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF010A0059

Major

Yes

Impact on the System

Reconstruction fails and system reliability decreases.

Possible Causes

  • The member disk is faulty or removed.
  • The remaining hot spare capacity is lower than the threshold.

Procedure

  1. Check whether any disk in the disk domain is removed.

    1. If yes, reinsert the removed disks. If the alarm persists=> Step2.
    2. If no=> Step2.

  2. Check whether faulty disks exist in the disk domain.

    1. If yes, replace the faulty disks. After the reconstruction of the faulty disk is completed, if the alarm persists=> Step3.
    2. If no=> Step3.

  3. Check whether any disk is about to become faulty in the disk domain.

    1. If yes, replace faulty disks after the pre-copy is completed. After the replacement, if the alarm persists=> Step4.
    2. If no=> Step4.

  4. Add disks to the disk domain. After the disks are added, if the alarm persists=> Step5.
  5. Collect all related information and contact technical support engineers.
Translation