This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF010A005B The Usage Of Effective Capacity Is High

0xF010A005B The Usage Of Effective Capacity Is High

Description

The used capacity is about to reach the upper limit of effective capacity.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF010A005B

Warning

Yes

Impact on the System

The usage of effective capacity of disk domain (name [pool-name]) is high. Current storage services are not affected. If the amount of data written to storage pools in the disk domain reaches the effective capacity ([effective-capacity]), storage performance will decrease. If the amount of data written to storage pools in the disk domain reaches ([over-capacity]), the storage space will become read-only.

Possible Causes

The amount of data written to storage pools in the disk domain reaches the alarm threshold. The idle rate of effective capacity is low.

Procedure

  1. Delete or migrate some data to reduce the used storage capacity. After the operation, if the alarm persists=> Step2.
  2. Collect related information and contact technical support engineers.