This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0CE0005 Disk Enclosure Temperature Exceeds The Upper Limit

0xF0CE0005 Disk Enclosure Temperature Exceeds The Upper Limit

Description

The working temperature of a disk enclosure exceeds the upper limit.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF0CE0005

Major

Yes

Impact on the System

The temperature of disk enclosure exceeds the normal working temperature, which may affect the normal operation of the storage system.

Possible Causes

  • Fan modules are faulty.
  • Heat dissipation channels in the disk enclosure are blocked.
  • The ambient temperature exceeds the upper limit.

Procedure

  1. Check whether alarms are generated indicating fan module faults.

    1. If yes, replace the faulty fan modules. If alarm Disk Enclosure Temperature Exceeds the Upper Limit persists=> Step2.
    2. If no=> Step2.

  2. Check whether heat dissipation channels in the disk enclosure are blocked.

    1. If yes, clear the heat dissipation channels. If alarm Disk Enclosure Temperature Exceeds the Upper Limit persists=> Step3.
    2. If no=> Step3.

  3. Check whether the ambient temperature is too high.

    1. If yes, lower the existing air conditioners' temperature or add more air conditioners. If alarm Disk Enclosure Temperature Exceeds the Upper Limit persists=> Step4.
    2. If no=> Step4.

  4. Collect related information and contact technical support engineers.