This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0D1000A Incorrect Removal Of Interface Module

0xF0D1000A Incorrect Removal Of Interface Module

Description

The interface module is removed improperly.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF0D1000A

Critical

Yes

Impact on the System

Controllers may work improperly.

Possible Causes

  • The interface module is removed without following the correct procedure.
  • The interface module is damaged.

Procedure

  1. Check whether the interface module is removed based on the correct hot swap procedure.

    1. If yes=> Step2.
    2. If no, reinsert the interface module. If the system is still unable to identify the interface module, restart related controllers. If the alarm persists=> Step2.

  2. Check whether alarms on the interface module faults are generated.

    1. If yes, replace the faulty interface module. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Collect all related information and contact technical support engineers.