Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF0DD0001 Remote Replication Consistency Group Is Disconnected

0xF0DD0001 Remote Replication Consistency Group Is Disconnected

Description

A remote replication consistency group is disconnected abnormally.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF0DD0001

Major

Yes

Impact on the System

A consistency group is disconnected due to the link disconnection between two storage arrays. If the links are disconnected permanently, the consistency group must be deleted.

Possible Causes

  • Links are unstable.
  • The disk domain is faulty.
  • The primary LUN of the remote replication is faulty.
  • The secondary LUN of the remote replication is faulty.
  • The storage pool is full.

Procedure

  1. Check whether cables are working correctly.

    1. If yes=> Step2.
    2. If no, replace faulty optical fibers or network cables to ensure that all links work correctly. If the alarm persists=> Step2.

  2. Check whether alarms are generated for the storage pools that house the primary and secondary LUNs.

    1. If yes, perform the recommended actions for managing alarms. If the alarm persists=> Step3.
    2. If no=> Step3.

  3. Check whether alarms are generated on the primary and secondary LUNs and their disk domains.

    1. If yes, perform the recommended actions for managing alarms. If the alarm persists=> Step4.
    2. If no=> Step4.

  4. Collect all related information and contact technical support engineers.
Translation