This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C040003 The Host Has An Incorrect Access Permission For HyperMetro Consistency Group

0xF3C040003 The Host Has An Incorrect Access Permission For HyperMetro Consistency Group

Description

The host has incorrect access permissions for HyperMetro consistency group. It can access the remote member LUN but cannot access the local member LUN.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF3C040003

Critical

Yes

Impact on the System

After the HyperMetro is disconnected, the host may be assigned access permissions for both the member LUNs, which may cause data inconsistency.

Possible Causes

When the active-active relationship is abnormal, the local member LUN wins the arbitration, but the remote member LUN is forcibly started.

Procedure

  1. Check whether the remote member LUN is forcibly started.

    1. If yes=> Step2.
    2. If no=> Step4.

  2. Check whether data on the local member LUN can be overwritten based on service access.

    1. If yes=> Step3.
    2. If no=> Step4.

  3. Start synchronization for the HyperMetro. If the alarm persists after the synchronization=> Step4.
  4. Collect all related information and contact technical support engineers.