Event Reference

OceanStor Dorado V3 Series V300R001

This document is applicable to OceanStor Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. This document describes the basic knowledge about the events of storage system in terms of event definition, event level, impact on the system, possible cause, and handling procedure. The document that you browse online matches the latest C version of the product. Click Download to download documents of other C versions.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
0xF3C050001 Latency Of The Link Connected To The Quorum Server Exceeds The Maximum Latency

0xF3C050001 Latency Of The Link Connected To The Quorum Server Exceeds The Maximum Latency

Description

Latency of the link connected to the quorum server exceeds the maximum latency.

Applicable Model

Applicable to all models.

Attribute

ID

Event Level

Automatically Cleared

0xF3C050001

Warning

Yes

Impact on the System

Latency of the link connected to the quorum server exceeds the upper limit, which influences the link communication between the storage array and the quorum server and reduces active-active reliability.

Possible Causes

Latency of the link between the quorum server and the storage array exceeds the maximum latency.

Procedure

  1. Run the ping command on the quorum server to check whether latency of the network between the quorum server and the storage array exceeds the maximum latency.

    1. If yes, rectify the network between the quorum server and the storage array=> Step2.
    2. If no=> Step3.

  2. Run the ping command to query whether the network latency decreases and is smaller than the recommended value 50 ms.

    1. If yes, and the alarm is not cleared after two minutes=> Step3.
    2. If no=> Step3.