No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.25 hwCfmVlanTwowayDelay

EOAM_Y1731_1.3.6.1.4.1.2011.5.25.136.1.6.25 hwCfmVlanTwowayDelay

Description

EOAM_Y1731/4/VLAN_2DM_EXCEED_THRESHOLD:OID [OID] The result of two-way delay-measure exceeded the threshold. (MdIndex=[GAUGE], MaIndex=[GAUGE], RemoteMacAddress=[OPAQUE], Timestamp=[TIMETICK], DelayValue=[GAUGE], ThresholdValue=[GAUGE])

In the VLAN networking where two-way frame delay measurement was configured and the expected alarm threshold was set, if the network delay exceeded the set alarm threshold, an alarm was generated.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.136.1.6.25 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

MdIndex

Index of the MD where a two-way frame delay alarm is generated

MaIndex

Index of the MA where a two-way frame delay alarm is generated

RemoteMacAddress

Source MAC address contained in the DMR frame received by the local end from the remote end

Timestamp

Timestamp indicating the time when a two-way frame delay alarm is generated

DelayValue

Delay when a two-way frame delay alarm is generated

ThresholdValue

An alarm threshold for two-way frame delay measurement

Impact on the System

Services will not be affected.

Possible Causes

The device was enabled with two-way frame delay measurement and was configured with an alarm threshold, and the delay in bidirectional frame transmission exceeded the alarm threshold.

Procedure

  1. Run the trace mac-8021ag command to check whether there is a long delay on the link or device on the network.

    • If there is such a long delay, go to Step 2.

    • If there is no such a long delay, go to Step 3.

  2. Troubleshoot the fault of a long delay. Then, check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 4.

    • If the alarm is not cleared, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.