Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume 67967

SRM_1.3.6.1.4.1.2011.5.25.129.2.1.10 hwEntityResume 67967

Description

SRM/4/POWERPRESENT: OID [oid] Power is present. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

The power supply unit of a device is installed again.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25 .129.2.1.10 Warning equipmentAlarm (5)

Parameters

Name Meaning

OID

Indicates the ID of the MIB object.

EntityPhysicalIndex

Indicates the index of the physical entity.

BaseTrapSeverity

Indicates the severity level.

BaseTrapProbableCause

Indicates the error code.
NOTE:

The error code for a power supply recovery alarm is 67967.

BaseTrapEventType

Indicates the event type.

EntPhysicalContainedIn

Indicates the code of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

RelativeResource

Indicates the sub-entity.

ReasonDescription

Indicates the fault description.

Impact on the System

Services are not affected.

Possible Causes

  • The internal power module is powered on.
  • The internal power module is installed on the device.
  • A lithium battery is installed on the device.
  • A lead-acid battery is installed on the device.

Procedure

  • None.