Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.5.2 hwPatchActiveOverTimeTrap

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.5.2 hwPatchActiveOverTimeTrap

Description

SYSMIB/4/PAT_OVERTIME:OID [oid] The patch is active for 24 hours.

Indicates that the patch was activated for 24 hours by running the patch active command. The patch, however, was not in the running state by running the patch run command.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.5.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

The newly-loaded patches, after the restart of the system, cannot be validated after the next restart.

Possible Causes

Cause 1:

The patch was activated for 24 hours, but not set into the running state.

Cause 2:

The RPC was busy in communication or memory was insufficient.

Procedure

  1. Run the display patch-information command to check the patch status.
  2. Check whether the patch is in the running state.

    • If so, go to Step 6.

    • If not, go to Step 3.

  3. To determine whether to set the patch to the running state, check whether the patch needs to be validated in next restart.

    • If so, go to Step 4.

    • If not, go to Step 6.

  4. Check whether the patch status goes into the running state after running the patch run command.

    • If so, go to Step 6.

    • If not, go to Step 5.

  5. Collect alarm information and configuration information, and then contact technical support personnel.
  6. End.

Related Information

None