No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TRUNK_1.3.6.1.4.1.2011.5.25.41.3.28 hwextallmemberdownnotify

TRUNK_1.3.6.1.4.1.2011.5.25.41.3.28 hwextallmemberdownnotify

Description

TRUNK/3/AMDN:OID [OID] The last member interface link status changes to down. (TrunkIfIndex=[INTEGER], TrunkName=[OCTET])

The status of all Trunk member interfaces became Down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.28 Minor other(1)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

TrunkIfIndex

Indicates the Trunk interface index.

TrunkName

Indicates the name of the Trunk interface.

Impact on the System

The interface cannot forward packets normally.

Possible Causes

The status of all Trunk member interfaces became Down.

Procedure

  1. Run the display this command in the Trunk interface view to check whether the Trunk interface is shut down.

    • Y=>2

    • N=>3

  2. Run the undo shutdown command in the Trunk interface view to check whether the alarm is cleared.

    • Y=>8

    • N=>3

  3. Run the display this command in the member interface view to check whether member interfaces are shut down.

    • Y=>4

    • N=>5

  4. Run the undo shutdown command in the member interface view to check whether the alarm is cleared.

    • Y=>8

    • N=>5

  5. Check whether the cable and optical module are loosened or dropped.

    • Y=>7

    • N=>6

  6. Connect the physical link correctly and then check whether the alarm is cleared.

    • Y=>8

    • N=>7

  7. Collect alarm information and configuration information, and then contact technical support personnel.
  8. End.