Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DHCP_1.3.6.1.4.1.2011.5.25.112.2.9 hwSnpUserNumberAlarmIfResume

DHCP_1.3.6.1.4.1.2011.5.25.112.2.9 hwSnpUserNumberAlarmIfResume

Description

DHCP/4/DHCPUSERBINDTRAPIFRESUME:OID [OID] The number of DHCP users on the interface descends to alarm threshold. (IfIndex=[INTEGER], VlanIndex=[INTEGER], Interface=[OCTET], CurrentUser=[INTEGER], MaxUser=[INTEGER])

The number of DHCP users connected to an interface reaches the lower alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.112.2.9 Warning equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

IfIndex

Indicates the interface index.

VlanIndex

Indicates the VLAN index. The value is 0.

Interface

Indicates the interface name of the device.

CurrentUser

Indicates the number of current access users.

MaxUser

Indicates the maximum number of access users.

Impact on the System

None.

Possible Causes

The number of DHCP snooping binding entries on an interface reaches the lower alarm threshold.

Procedure

  1. Run the dhcp snooping max-user-number max-user-number command to adjust the maximum number of access users allowed on the interface.
  2. Run the dhcp snooping user-alarm percentage percent-lower-value percent-upper-value command to adjust the alarm thresholds.

Related Information

None.