Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
POE_1.3.6.1.4.1.2011.5.25.195.40.10 hwPoePdClassInvalid

POE_1.3.6.1.4.1.2011.5.25.195.40.10 hwPoePdClassInvalid

Description

POE/4/PDINVALIDCLASS: OID [oid] PD with invalid IEEE class and power denied.(IfIndex=[INTEGER], Interface="[OCTET]")

The system detects that the PD class is invalid.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.195.40.10 Warning communicationsAlarm(2)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
IfIndex Indicates the interface index.
Interface Indicates the interface name.

Impact on the System

Services are not affected.

Possible Causes

Cause 1:

The PD may not comply with standards, whereas the switch supports 802.3af and 802.3at. In this case, the PD class cannot be identified by the switch.

Cause 2:

The PD hardware is faulty.

Cause 3:

The PoE chip of the device is faulty.

Procedure

  1. Run the poe legacy enable command on the interface to enable compatibility detection and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, go to step 2.

  2. Replace the PD with a standard PD and then check whether the alarm is cleared.

    If so, the alarm handling ends.

    If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None