Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
TRUNK_1.3.6.1.4.1.2011.5.25.41.3.39 hwExtTrunkMemberCountExceedThreshold

TRUNK_1.3.6.1.4.1.2011.5.25.41.3.39 hwExtTrunkMemberCountExceedThreshold

Description

TRUNK/4/MEMBER_COUNT_EXCEED_THRESHOLD: OID [OID] The number of members of the Eth-Trunk in LACP mode exceeded the upper threshold.(UpperThreshold=[INTEGER])

The number of the member interfaces of an Eth-Trunk interface in LACP mode exceeded the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.39 Warning other(1)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

UpperThreshold

Upper threshold for the number of the member interfaces of an Eth-Trunk interface in LACP mode

Impact on the System

Services will not be affected.

Possible Causes

The number of the member interfaces of an Eth-Trunk interface in LACP mode exceeded the upper threshold.

Procedure

  1. Run the display eth-trunk command to check whether the member interfaces of all Eth-Trunks that work in LACP mode are being used in Up state and have traffic. If there is any member interface that is not being used, run the undo eth-trunk command in the corresponding interface view to configure the member interface to leave the Eth-Trunk that works in LACP mode. Check whether the alarm is cleared.

    • If the alarm is cleared, go to Step 3.
    • If the alarm persists, go to Step 2.

  2. Collect alarm information and configuration information, and then contact technical support personnel.
  3. End.