Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm 140545

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.10.13 hwBrdTempAlarm 140545

Description

ENTITYTRAP/1/ENTITYBRDTEMPALARM: OID [oid] Temperature rise over or fall below the warning alarm threshold. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID=[INTEGER])

The temperature of the board falls below the lower threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.10.13 Critical environmentalAlarm(6)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the index.
EntityPhysicalIndex Indicates the index of the physical entity.
PhysicalName Indicates the name of the physical entity.
EntityThresholdType Indicates the threshold type of the physical entity.
EntityThresholdValue Indicates the threshold value of the physical entity.
EntityThresholdCurrent Indicates the current value of the physical entity.
EntityTrapFaultID Indicates the error code.

Impact on the System

Services on the board may be affected if the temperature becomes too low.

Possible Causes

The ambient temperature is too low.

Procedure

  1. Measure the ambient temperature. If the ambient temperature is too low, use air conditioners or heaters to increase the temperature.
  2. If the ambient temperature is normal, the lower threshold of the temperature may be too high. Run the temperature threshold slot slotid lower-limit lower upper-limit upper command to decrease the lower threshold of the temperature.