No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
POE_1.3.6.1.4.1.2011.5.25.195.40.16 hwPoePdPriorityDifferent

POE_1.3.6.1.4.1.2011.5.25.195.40.16 hwPoePdPriorityDifferent

Description

POE/4/PDPRIDIFF: OID [oid] priority inconsistent.(IfIndex=[INTEGER], Interface="[OCTET]", PortPriority=[INTEGER], PDPriority=[INTEGER])

The interface priority is different from the PD priority.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.195.40.16 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
IfIndex Indicates the interface index.
Interface Indicates the interface name.
PortPriority Indicates the interface priority.
PDPriority Indicates the PD priority.

Impact on the System

Services are not affected.

Possible Causes

The interface prioriry is low, whereas the PD priority is high.

Procedure

  1. Run the poe priority command to change the interface priority to be higher than the PD priority.

Related Information

None

Translation
Download
Updated: 2019-09-24

Document ID: EDOC1000141873

Views: 158268

Downloads: 15

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next