Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SW_SNPG_1.3.6.1.4.1.2011.5.25.44.99.2 hwMCastTableLoadAbnormalNotify

SW_SNPG_1.3.6.1.4.1.2011.5.25.44.99.2 hwMCastTableLoadAbnormalNotify

Description

SW_SNPG/4/NOTIFYTRAP:[OID] Multicast table of router was full.

The number of Layer 2 multicast forwarding entries has reached the upper limit allowed by the system.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.44.99.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Impact on the System

New multicast forwarding entries cannot be configured or learned on the switch.

Possible Causes

The total number of Layer 2 multicast forwarding entries exceeded 90% of the upper limit.

Procedure

  1. Run the display igmp-snooping port-info command to view forwarding entries of all multicast groups, and then check whether unnecessary static multicast entries exist.

    • If so, go to step 2.

    • If not, no further action is required.

  2. Run the undo l2-multicast static-group group-address x.x.x.x command to delete unnecessary multicast entries, and check whether the alarm hwMCastTableLoadAbnormalResume is generated.

    • If so, no further action is required.

    • If not, go to step 3.

  3. Collect alarm, log, and configuration information, and contact technical support personnel.