Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.5 hwStackSystemRestart

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.5 hwStackSystemRestart

Description

FSP/4/STACK_RESTART: OID [oid] After stack restart, the new master is slot [integer].

This alarm was sent to the NMS by the master switch after all the switches in the stack system were restarted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
[OID] Indicates the OID of the MIB.
[integer] Indicates the stack ID of the device generating the alarm.

Impact on the System

During the restart of the stack system, services are interrupted. After the restart of the stack system, services recover.

Possible Causes

1. The reboot command was manually run on the master switch to restart the stack system.

2. The master and standby switches in the stack system were powered off at the same time.

3. All the switches in the stack system were powered off at the same time.

Procedure

  1. Check whether the stack system was manually restarted using the reboot command.

    • If so, the alarm handling ends.

    • If not, go to step 2.

  2. Check whether the stack system was powered off.

    • If so, the alarm handling ends.

    • If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None