Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.7 hwStackStackMemberLeave

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.7 hwStackStackMemberLeave

Description

FSP/4/STACKMEMBER_LEAVE: OID [oid] Slot [integer] leaves from stack.

This alarm was generated when a member switch left the stack system.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.7 Warning equipmentAlarm(5)

Parameters

Name Meaning
[OID] OID of the MIB
[integer] Stack ID of the device generating the alarm

Impact on the System

The services that are forwarded through the device are interrupted.

Possible Causes

1. A switch was manually removed from the stack system.

2. A switch in the stack system was powered off.

3. The stack cable connecting a switch in the stack system was removed.

Procedure

  1. Check whether the switch was manually removed from the stack system.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Check whether the switch was manually powered off.

    • If so, power on it. The alarm handling ends.
    • If not, go to step 3.

  3. Check whether the stack cable of the switch was loose.

    • If so, install the stack cable securely. The alarm handling ends.
    • If not, collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None

Translation