Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135193

ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135193

Description

ENTITYTRAP/2/CARDFAIL: OID [oid] Card become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])

The charge temperature of a lithium battery is too high.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the alarm index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity where the alarm is generated.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm.

Impact on the System

The high charge temperature may affect operation of the lithium battery.

Possible Causes

The normal charge temperature for a lithium battery is 0°C to 450°C. If the ambient temperature exceeds the upper threshold during charge of the lithium battery, the system generates a high charge temperature alarm.

Procedure

  1. Check whether the air vent for the lithium battery is blocked and whether the fans are running normally. Fix the problem (if any) to ensure that fans are running normally.
  2. Contact technical support personnel.