Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SCMTRAP_1.3.6.1.4.1.2011.5.25.334.2.1.3 hwSrvServiceConfigFailed

SCMTRAP_1.3.6.1.4.1.2011.5.25.334.2.1.3 hwSrvServiceConfigFailed

Description

SCMTRAP/3/SRVSERCONFIGFAILED: OID [oid] The service configurations on the device failed because of no enough resources or hash conflict, please undo it. (Service ID=[INTEGER], Service Description="[OCTET]", Service Fail Description="[OCTET]")

The service configurations failed because resources were insufficient or a hash conflict occurred.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.334.2.1.3 Minor qualityOfServiceAlarm (3)

Parameters

Name Meaning
OID Indicates the ID of the alarm MIB object.
Service ID Indicates the service ID.
Service Description Indicates service description.
Service Fail Description Indicates service failure description.

Impact on the System

The configurations do not take effect and services are unavailable.

Possible Causes

Resources were insufficient or a hash conflict occurred when services were being configured.

Procedure

  • Obtain information about the service configurations that fail to be delivered according to Service Fail Description and delete the corresponding service configuration commands.

    • If the service configurations are required, collect alarm information and configuration information, and then contact technical support personnel.
    • If the service configurations are not required, the alarm handing ends.

Related Information