Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.2.4 hwTempFallingResume

SRM_1.3.6.1.4.1.2011.5.25.129.2.2.4 hwTempFallingResume

Description

SRM/4/TEMPFALLINGRESUME:OID [OID] temperature below minor threshold resumes. (EntityPhysicalIndex=[INTEGER1], BaseThresholdEntry_entPhysicalIndex=[INTEGER2], BaseThresholdEntry_hwBaseThresholdType=[INTEGER3], BaseThresholdEntry_hwBaseThresholdIndex=[INTEGER4], BaseTrapSeverity=[INTEGER5], BaseTrapProbableCause=[INTEGER6], BaseTrapEventType=[INTEGER7], EntPhysicalName=[OCTET], BaseThresholdValue=[INTEGER8], BaseThresholdUnit=[INTEGER9], BaseThresholdLowWarning=[INTEGER10], BaseThresholdLowCritical=[INTEGER11])

This alarm was generated when the temperature restored to a normal value from the lower threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.2.4 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID OID of the MIB
EntityPhysicalIndex Entity index
BaseThresholdEntry_entPhysicalIndex Index of the entity causing this temperature alarm
BaseThresholdEntry_hwBaseThresholdType Type of the detected entity (The value 1 indicates the temperature sensor of a certain type that is adopted by the S-switch.)
BaseThresholdEntry_hwBaseThresholdIndex Index of the temperature sensor (The value begins from 1.)
BaseTrapSeverity Severity code
BaseTrapProbableCause Error code
BaseTrapEventType Code of the event type
EntPhysicalName Entity name
BaseThresholdValue Current temperature
BaseThresholdUnit Unit of the temperature
BaseThresholdLowWarning Lower threshold of the temperature
BaseThresholdLowCritical Major lower threshold of the temperature

Impact on the System

None

Possible Causes

1. The lower threshold of the temperature was set to a proper value.

2. The ambient temperature increased to be higher than the lower threshold.

Procedure

  • No action is required.