Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RRPP_1.3.6.1.4.1.2011.5.25.113.4.2 hwRrppRingFail

RRPP_1.3.6.1.4.1.2011.5.25.113.4.2 hwRrppRingFail

Description

RRPP/2/RNGDN:OID [oid] Domain [domain-id] ring [ring-id] is failed.

A link on the ring network was faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.113.4.2 Major equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

domain-id

Indicates the ID of an RRPP domain.

ring-id

Indicates the ID of an RRPP ring.

Impact on the System

Data flows will be interrupted in milliseconds when the link is switched.

Possible Causes

The complete ring became incomplete because a link was faulty on the ring.

Procedure

  1. Run the display rrpp verbose domain domain-id command to check whether the status of each interface is unknown.

    • If so, go to Step 3.

    • If not, go to Step 2.

  2. Run the display rrpp verbose domain domain-id command to check whether the status of each interface is Down.

    • If so, go to Step 5.

    • If not, go to Step 9.

  3. Check whether the interface board corresponding to the port is pulled out.

    • If so, go to Step 7.

    • If not, go to Step 2.

  4. Run the display this command on the interface to check whether the interface is shut down.

    • If so, go to Step 5.

    • If not, go to Step 6.

  5. Run the undo shutdown command in the interface view to check whether the alarm is cleared.

    • If so, go to Step 10.

    • If not, go to Step 6.

  6. Check whether devices or links between devices are faulty.

    • If so, go to Step 8.

    • If not, go to Step 9.

  7. Insert the board correctly and then check whether the alarm is cleared.

    • If so, go to Step 10.

    • If not, go to Step 2.

  8. Repair devices or links between devices and then check whether the alarm is cleared.

    • If so, go to Step 10.

    • If not, go to Step 9.

  9. Collect alarm information and configuration information, and then contact technical support personnel.
  10. End.