No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.5.12 hwPortPhysicalEthFullDuplexClear

SRM_1.3.6.1.4.1.2011.5.25.129.2.5.12 hwPortPhysicalEthFullDuplexClear

Description

SRM/4/HALFDUPLEXCLEAR: OID [oid] The port works in full duplex mode.(EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalName=[OCTET],RelativeResource="[OCTET]")

The interface working mode changed to full duplex.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.5.12 Warning communicationsAlarm(2)

Parameters

Name Meaning
[oid] Indicates the OID of the alarm.
EntityPhysicalIndex Indicates the interface index.
BaseTrapSeverity Indicates the alarm severity.
BaseTrapProbableCause Indicates the alarm cause.
BaseTrapEventType Indicates the alarm type.
EntPhysicalName Indicates the interface name.
RelativeResource Indicates the relative resource.

Impact on the System

The interface alternates between Up and Down states.

Possible Causes

The interface begins to work in half duplex mode. When the interface works in full duplex mode, a full duplex alarm is generated.

Procedure

  1. Check whether the duplex state of the interface is correct according to networking requirements.

    Run the display interface interface-type [ interface-number ] command to check the duplex state of the interface.

    • If the duplex state of the interface is incorrect, modify the interface configuration.
    • If the duplex state of the interface is correct, go to step 2.

  2. End.