Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LACP_1.3.6.1.4.1.2011.5.25.41.3.15 hwLacpPartialLinkLossResume

LACP_1.3.6.1.4.1.2011.5.25.41.3.15 hwLacpPartialLinkLossResume

Description

LACP/2/PLR:OID [oid] Link bandwidth lost partly is resumed. (TrunkIndex=[INTEGER], TrunkIfIndex=[INTEGER], TrunkId=[INTEGER], TrunkName=[OCTET])

It is a trap indicating the restoration of the partial link bandwidth and is a matching trap of hwLacpPartialLinkLoss.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.3.15

Major

operationalViolation(8)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

TrunkIndex

Indicates the index of a trunk.

TrunkIfIndex

Indicates the index of a trunk interface.

TrunkId

Indicates the ID of a trunk interface.

TrunkName

Indicates the name of a trunk interface.

Impact on the System

Part of services were resumed.

Possible Causes

1.

Because the number of trunk member links that could go Up through negotiation was below the minimum number of Up member links, the link aggregation group went Down, and thus the trap hwLacpPartialLinkLoss was generated. When the fault was rectified, the trap hwLacpPartialLinkLossResume was generated.

Procedure

  • This alarm message is informational only, and no action is required.