Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
VCMP_1.3.6.1.4.1.2011.5.25.42.3.1.4.2 hwVcmpServerMacConflict

VCMP_1.3.6.1.4.1.2011.5.25.42.3.1.4.2 hwVcmpServerMacConflict

Description

VCMP/4/VCMP_MULTI_SERVER:OID [oid] More than one server exists in the VCMP domain. (VcmpDeviceMac=[OPAQUE])

Multiple VCMP servers coexisted in a VCMP domain.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.3.1.4.2 Warning other(1)

Parameters

Name Meaning
oid Indicates the ID of a MIB object.
VcmpDeviceMac Indicates the MAC address of a conflicting server.

Impact on the System

If this alarm is generated, more than one VCMP server exists in a VCMP domain. VCMP clients learn VLAN information sent by all VCMP servers. For example, there are two VCMP servers in a VCMP domain. VLAN 10 is created on one VCMP server and deleted from the other VCMP server. The VCMP clients in the same VCMP domain create and the delete VLAN 10, causing a communication failure.

Possible Causes

The VCMP configuration was incorrect.

Procedure

  1. Run the display vcmp status command on each device in the VCMP domain to view the Role field. Check whether more than one device functions as the VCMP server.

    • If only a single device functions as the VCMP server, go to step 3.

    • If more than one device functions as the VCMP server, go to step 2.

  2. Run the vcmp role { client | silent | transparent } command on a VCMP server to change its role to a non-server device. Check whether the alarm is cleared.

    • If the alarm is cleared, no further action is required.

    • If the alarm persists, go to step 3.

  3. Collect alarm, log, and configuration information, and contact technical support personnel.

Related Information

None

Translation
Download
Updated: 2019-04-18

Document ID: EDOC1000141873

Views: 111477

Downloads: 14

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next