No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.61 hwStackSetUpFailure

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.61 hwStackSetUpFailure

Description

FSP/3/SETUPFAILURE: OID [OID] Failed to set up a stack. (LocalSlotID =[integer], PeerSlotID=[integer], Reason=[STRING])

A stack fails to be set up.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.61 Minor communicationsAlarm (2)

Parameters

Name Meaning
OID ID of a MIB object.
LocalSlotID Indicates the slot ID of the local stack member switch.
PeerSlotID Indicates the slot ID of the remote stack member switch.
Reason Indicates the reason why the stack fails to be set up.

Impact on the System

Services cannot run normally.

Possible Causes

The switches cannot set up a stack because of a device model mismatch.

Procedure

  1. Run the display device command to check the switch model.
  2. Use switches of the same model or different models that allow to set up a stack together based on Stack Configuration Notes.