No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.41 hwPhyStackPortErrorDown

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.41 hwPhyStackPortErrorDown

Description

FSP/2/ERRORDOWN: OID [OID] Runts-error-down occured (Stack port = [octet]).

An error-down event occurred on a physical member port that has been added to a logical stack port.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.41 Major communicationsAlarm (2)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
Stack port Indicates the local port name.

Impact on the System

The port is in error-down state. The stack may split because the port is unavailable.

Possible Causes

The port receives error packets.

Procedure

  1. Check whether there are unstable or incorrect connections as well as faulty lines.
  2. If the connections are stable and correct and lines are normal, run the shutdown and undo shutdown command on the physical port.