Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.1.13 hwEntityOffline

SRM_1.3.6.1.4.1.2011.5.25.129.2.1.13 hwEntityOffline

Description

SRM/3/ENTITYOFFLINE:OID [OID] fan pull out. (EntityPhysicalIndex[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])

This alarm was generated when the fan module was removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.1.13 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID OID of the MIB
EntityPhysicalIndex Entity index
BaseTrapSeverity Severity code
BaseTrapProbableCause Error code
BaseTrapEventType Code of the event type
EntPhysicalContainedIn Entity code
EntPhysicalName Entity name
RelativeResource Name of the affected component
ReasonDescription Fault description

Impact on the System

After the fan module is removed, the temperature of the board increases, which may result in faults on the device. That is, packet loss may occur or even more seriously, the device may be suspended or abnormally reset.

Possible Causes

The fan module was removed.

Procedure

  1. Run the display device command to check whether the fan subcard is installed properly.

    • If so, go to step 2.

    • If not, install the fan subcard and the alarm handling ends.

  2. Remove and reinstall the fan subcard to check whether the alarm is cleared in case the alarm is mistakenly reported.

    • If so, the alarm handling ends.

    • If not, collect alarm information and configuration information, and then contact technical support personnel.