Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.15.1 hwMemUtilizationRising

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.15.1 hwMemUtilizationRising

Description

ENTITYTRAP/4/ENTITYMEMORYALARM: OID [oid] Memory usage exceeded the threshold, and it may cause the system to reboot. (Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityThresholdType=[INTEGER], EntityThresholdValue=[INTEGER], EntityThresholdCurrent=[INTEGER], EntityTrapFaultID= [INTEGER].)

The memory usage exceeds the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.15.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the alarm MIB object.
Index Indicates the alarm ID.
EntityPhysicalIndex Indicates the index of the physical entity where the alarm is reported.
PhysicalName Indicates the physical entity name.
EntityThresholdType Indicates the alarm type.
EntityThresholdValue Indicates the alarm threshold.
EntityThresholdCurrent Indicates the current memory usage.
EntityTrapFaultID Indicates the error code of the alarm.

Impact on the System

The high memory usage will delay processing of some services.

Possible Causes

The memory usage of the device exceeds the alarm threshold.

Procedure

  1. Rectify the fault according to High Memory Usage in the Revelations of Troublesolving-Campus Switch-Device Management And Maintenance.