No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.6 hwCardInvalidResume 135450-135458

ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.6 hwCardInvalidResume 135450-135458

Description

ENTITYTRAP/4/CARDINVALIDRESUME: OID [oid] Card resume from invalid situation.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])

The faulty lithium battery has been removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.6 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the alarm index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity where the alarm is generated.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm.
NOTE:
The error code depends on the fault that has occurred on the lithium battery:
  • 135450: The removed lithium battery has a short-circuit fault on the charge switch.
  • 135451: The removed lithium battery has an open-circuit fault on the charge switch.
  • 135452: The removed lithium battery has a short-circuit fault on the discharge switch.
  • 135453: The removed lithium battery has an open-circuit fault on the discharge switch.
  • 135454: The removed lithium battery has a short-circuit fault on the charge and discharge switches.
  • 135455: The removed lithium battery has an open-circuit fault on the charge and discharge switches.
  • 135456: The removed lithium battery has another type of internal fault.
  • 135457: The electrochemical cell of the removed lithium battery is faulty.
  • 135458: The removed lithium battery encounters a temperature collection failure.

Impact on the System

If you do not install a new lithium battery in the device, the device cannot work when the external power supply is shut down.

Possible Causes

The faulty lithium battery is removed.

Procedure

  • Install a new lithium battery in the device.
Translation