Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 136192

SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 136192

Description

SRM/3/SFP_EXCEPTION:OID [oid] Optical module exception, SFP is not certified. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

An optical module installed on the device is not a Huawei-customized optical module.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.1.9 Minor equipmentAlarm (5)

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

EntityPhysicalIndex

Indicates a physical entity index.

BaseTrapSeverity

Indicates the alarm severity.

BaseTrapProbableCause

Indicates the error code of the alarm.

BaseTrapEventType

Indicates the event type.

EntPhysicalContainedIn

Indicates contained physical entity code.

EntPhysicalName

Indicates the physical entity name.

RelativeResource

Indicates the entity-related resources.

ReasonDescription

Describes reason of the fault.

Impact on the System

If this optical module was delivered from Huawei early, this alarm does not affect the system. If not, the optical module may not work normally.

Possible Causes

The optical module is not a Huawei-customized optical module. Vendor information of the early delivered Huawei optical module is not recorded.

Procedure

  • If this optical module was delivered from Huawei earlier, run the transceiver phony-alarm-disable command to disable the alarm function for non-Huawei customized optical modules.
  • If this optical module is not delivered from Huawei or is not customized for Huawei, replace it with a Huawei-customized optical module.