Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.2.1 hwTempRisingAlarm

SRM_1.3.6.1.4.1.2011.5.25.129.2.2.1 hwTempRisingAlarm

Description

SRM/3/TEMPRISINGALARM: OID [OID] temperature over high threshold .(EntityPhysicalIndex=[INTEGER1], BaseThresholdEntry_entPhysicalIndex=[INTEGER2], BaseThresholdEntry_hwBaseThresholdType=[INTEGER3], BaseThresholdEntry_hwBaseThresholdIndex=[INTEGER4], BaseTrapSeverity=[INTEGER5], BaseTrapProbableCause=[INTEGER6], BaseTrapEventType=[INTEGER7], EntPhysicalName=[OCTET], BaseThresholdValue=[INTEGER8], BaseThresholdUnit=[INTEGER9], BaseThresholdHighWarning=[INTEGER10], BaseThresholdHighCritical=[INTEGER11])

The temperature exceeded the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.2.1 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID OID of the MIB.
EntityPhysicalIndex Entity index.
BaseThresholdEntry_entPhysicalIndex Index of the entity causing this temperature alarm.
BaseThresholdEntry_hwBaseThresholdType Type of the detected entity (The value 1 indicates the temperature sensor of a certain type that is adopted by the S-switch.).
BaseThresholdEntry_hwBaseThresholdIndex Index of the temperature sensor (The value begins from 1.).
BaseTrapSeverity Severity code.
BaseTrapProbableCause Error code.
BaseTrapEventType Code of the event type.
EntPhysicalName Entity name.
BaseThresholdValue Current temperature.
BaseThresholdUnit Unit of the temperature.
BaseThresholdLowWarning Upper threshold of the temperature.
BaseThresholdLowCritical Major upper threshold of the temperature.

Impact on the System

When the temperature exceeds the upper threshold, the switch may not work properly and packet loss may occur. Or more seriously, the system may not respond or reset abnormally.

Possible Causes

  • The chassis is not ventilated well, which causes heat unable to be dissipated.

  • The ambient temperature is high.

  • There are not enough fans in the switch.

  • One or more fans in the switch have failed.

  • The upper threshold of the temperature is too low.

Procedure

  1. Clean the air vents and check whether the alarm is cleared.

    (1) If so, go to step 13.

    (2) If not, go to step 2.

  2. Check whether the ambient temperature is high.

    (1) If so, go to step 3.

    (2) If not, go to step 4.

  3. Lower the temperature in the equipment room, and then go to step 4.
  4. Check whether all the fans are present and working normally.

    (1) If so, go to step 6.

    (2) If not, go to step 5.

  5. Install more fans in the switch, and then go to step 6.
  6. Run the display fan command to check the status of fans and determine whether any fan is faulty.

    (1) If so, go to step 7.

    (2) If not, go to step 8.

  7. Replace the faulty fan, and then go to step 8.
  8. After the switch has been running for a period of time, run the display temperature all command to check whether temperature of the switch is still high.

    (1) If so, go to step 9.

    (2) If not, go to step 13.

  9. Check whether the upper threshold of the temperature is too low.

    (1) If so, go to step 10.

    (2) If not, go to step 12.

  10. Run the temperature threshold slot slotid lower-limit lower upper-limit upper command to set a higher upper threshold of the temperature.
  11. After the switch has been running for a period of time, run the display temperature all command to check whether temperature of the switch is still high.

    (1) If so, go to step 12.

    (2) If not, go to step 13.

  12. Contact technical support personnel.
  13. End.