Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.26 hwMstpPortCountExceedThreshold

MSTP_1.3.6.1.4.1.2011.5.25.42.4.2.26 hwMstpPortCountExceedThreshold

Description

MSTP/4/PORT_COUNT_EXCEED_THRESHOLD: OID [OID] The number of Up STP-capable interfaces exceeded the upper threshold, which may overload the CPU. Delete redundant member interfaces. (UpperThreshold=[INTEGER])

The number of STP interfaces that were Up on a device exceeded the upper threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.4.2.26 Warning communicationsAlarm(2)

Parameters

Name Meaning
OID Indicates the MIB object ID of the alarm.
UpperThreshold Upper threshold for the number of STP interfaces that are Up

Impact on the System

The CPU may be overloaded.

Possible Causes

Cause 1:

The number of STP interfaces that were Up on a device exceeded the upper threshold.

Procedure

  1. Run the display stp brief command and display interface brief command to check the STP interfaces that are Up.

    • If some of the interfaces can have SPT disabled, go to Step 2.

    • If all the interfaces cannot have SPT disabled, go to Step 3.

  2. Run the stp disable or undo stp enable command in the interface view to disable STP and check whether the device still receives this alarm.

    • If the device no longer receives this alarm, the alarm is cleared.

    • If the device still receives this alarm, the number of STP interfaces that are Up remains greater than the upper threshold. In this situation, go to Step 2.

  3. Collect alarm information and configuration information, and then contact technical support personnel.