Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 67967

SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 67967

Description

SRM/3/POWERABSENT: OID [oid] Power is absent. (EntityPhysicalIndex=[INTEGER], BaseTrapSeverity=[INTEGER], BaseTrapProbableCause=[INTEGER], BaseTrapEventType=[INTEGER], EntPhysicalContainedIn=[INTEGER], EntPhysicalName=[OCTET], RelativeResource=[OCTET], ReasonDescription=[OCTET])

The power supply unit of a device is removed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.1.9 Minor equipmentAlarm (5)

Parameters

Name Meaning

OID

Indicates the ID of the MIB object.

EntityPhysicalIndex

Indicates the index of the physical entity.

BaseTrapSeverity

Indicates the severity level.

BaseTrapProbableCause

Indicates the error code.

NOTE:

The error code for a power module removal alarm is 67967.

BaseTrapEventType

Indicates the event type.

EntPhysicalContainedIn

Indicates the code of the physical entity.

EntPhysicalName

Indicates the name of the physical entity.

RelativeResource

Indicates the sub-entity.

ReasonDescription

Indicates the fault description.

Impact on the System

If the device uses only one power supply, the device is powered off after the power supply is removed and services are interrupted.

Possible Causes

  • The internal power module encounters a power failure.
  • The internal power module is removed.
  • The lithium battery is removed.
  • The lead-acid battery is removed.

Procedure

  • Install the power supply.