Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L3MB_1.3.6.1.4.1.2011.5.25.227.2.1.22 hwBoardIPv6ACLResLack

L3MB_1.3.6.1.4.1.2011.5.25.227.2.1.22 hwBoardIPv6ACLResLack

Description

L3MB/4/IPV6RESOURCELACK:OID [OID] IPv6 cannot be enabled on the interface because of insufficient resources.(vlanif=[OCTET],Slot=[OCTET])

IPv6 could not be enabled on the interface because of insufficient system resources.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.227.2.1.22 Warning processingErrorAlarm(4)

Parameters

Name Meaning
OID Indicates the MIB object ID of the alarm.
vlanif Indicates the number of the VLANIF interface.
Slot Indicates the slot ID.

Impact on the System

The IPv6 service is unavailable in the VLANIF interface view.

Possible Causes

System resources were insufficient.

Procedure

  1. Adjust the usage of ACL resources.

    Run the display acl resource command to check ACL resource information. Run the undo ipv6 enable command in the VLANIF interface view to disable the IPv6 function. Delete some useless service configurations that occupy ACL resources to release the resources. Run the ipv6 enable command in the VLANIF interface view to enable the IPv6 function.

    After completing the preceding operations, check whether the alarm is cleared. If so, no further action is required; if not, go to step 2.

  2. Collect alarm, log, and configuration information, and contact technical support personnel.

Related Information

None