Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.2.3 hwTempFallingAlarm

SRM_1.3.6.1.4.1.2011.5.25.129.2.2.3 hwTempFallingAlarm

Description

SRM/3/TEMPFALLINGALARM:

OID [OID] temperature below minor threshold .(EntityPhysicalIndex=[INTEGER1], BaseThresholdEntry_entPhysicalIndex=[INTEGER2], BaseThresholdEntry_hwBaseThresholdType=[INTEGER3], BaseThresholdEntry_hwBaseThresholdIndex=[INTEGER4], BaseTrapSeverity=[INTEGER5], BaseTrapProbableCause=[INTEGER6], BaseTrapEventType=[INTEGER7], EntPhysicalName=[OCTET], BaseThresholdValue=[INTEGER8], BaseThresholdUnit=[INTEGER9], BaseThresholdLowWarning=[INTEGER10], BaseThresholdLowCritical=[INTEGER11])

This alarm was generated when the temperature was lower than the lower threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.2.3 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID OID of the MIB
EntityPhysicalIndex Entity index
BaseThresholdEntry_entPhysicalIndex Index of the entity causing this temperature alarm
BaseThresholdEntry_hwBaseThresholdType Type of the detected entity (The value 1 indicates the temperature sensor of a certain type that is adopted by the S-switch.)
BaseThresholdEntry_hwBaseThresholdIndex Index of the temperature sensor (The value begins from 1.)
BaseTrapSeverity Severity code
BaseTrapProbableCause Error code
BaseTrapEventType Code of the event type
EntPhysicalName Entity name
BaseThresholdValue Current temperature
BaseThresholdUnit Unit of the temperature
BaseThresholdLowWarning Lower threshold of the temperature
BaseThresholdLowCritical Major lower threshold of the temperature

Impact on the System

After the temperature exceeds the lower threshold, the device may fail to work normally. That is, packet loss may occur or even more seriously, the device may be suspended or abnormally reset.

Possible Causes

1. The lower threshold of the temperature was too high.

2. The ambient temperature was too low.

Procedure

  1. Run the display temperature { all | slot slot-id } command to check whether the ambient temperature is too low.

    • If so, increase the ambient temperature by turning up the air-conditioner.
    • If not, go to step 2.

  2. Run the display temperature { all | slot slot-id } command to check whether the set lower threshold of the temperature is too high.

    • If so, set the lower threshold of the temperature to a proper value. It is recommended that you run the undo temperature threshold unit unit-id command to restore the lower threshold to the default value.
    • If not, the alarm handling ends.