Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFPDT_1.3.6.1.4.1.2011.5.25.315.3.7 hwTrunkMemSpeedDifferentAlarm

IFPDT_1.3.6.1.4.1.2011.5.25.315.3.7 hwTrunkMemSpeedDifferentAlarm

Description

IFPDT/3/MEMSPEEDDIF:OID [OID] The active member ports in trunk have inconsistent bandwidth. (TrunkIfIndex=[INTEGER], TrunkName=[OCTET])

The rates of active interfaces of the Eth-Trunk were different.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.315.3.7 Minor equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the ID of a MIB object.

TrunkIfIndex

Indicates the index of an Eth-Trunk.

TrunkName

Indicates the name of an Eth-Trunk.

Impact on the System

Packet loss may occur on the member interface with low bandwidth.

Possible Causes

The rates of active interfaces of the Eth-Trunk were different.

Procedure

  1. Run the display Eth-Trunk [ trunk-id ] command to check whether the value of WorkingMode is NORMAL.

    • If the value of WorkingMode is NORMAL, go to 2.

    • If the value of WorkingMode is not NORMAL, go to 3.

  2. Check whether member interfaces use the same type and rate.

    • For electrical interfaces, if rates are manually configured and different, reconfigure the rates. If rates are not configured manually, go to 3.

    • For optical interfaces, if rates are manually configured and different or optical modules are of different types, reconfigure the rates or replace optical modules. If rates are not configured manually, go to 3.

  3. Contact technical support personnel.