Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.5 hwCardInvalid 135450-135458

ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.5 hwCardInvalid 135450-135458

Description

ENTITYTRAP/1/CARDINVALID:OID [oid] Card is invalid for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])

A lithium battery has failed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.5 Critical equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the alarm index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity where the alarm is generated.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm.
NOTE:
The error codes of different lithium battery faults are:
  • 135450: The charge switch of the lithium battery is in a short-circuit condition.
  • 135451: The charge switch of the lithium battery is in an open-circuit condition.
  • 135452: The discharge switch of the lithium battery is in a short-circuit condition.
  • 135453: The discharge switch of the lithium battery is in an open-circuit condition.
  • 135454: Both the charge and discharge switches of the lithium battery are in a short-circuit condition.
  • 135455: Both the charge and discharge switches of the lithium battery are in an open-circuit condition.
  • 135456: Other internal faults of the lithium battery.
  • 135457: The electrochemical cell of the lithium battery is faulty.
  • 135458: An error occurs when the system is collecting temperature of the lithium battery.

Impact on the System

The lithium battery may not work normally.

Possible Causes

The lithium battery has an internal fault.

Procedure

  • Replace the lithium battery.