Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135191

ENTITYTRAP 1.3.6.1.4.1.2011.5.25.219.2.3.3 hwCardFail 135191

Description

ENTITYTRAP/2/CARDFAIL: OID [oid] Card become failure for some reason.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapEntType= [INTEGER], EntityTrapFaultID=[INTEGER])

The temperature of a lithium battery is too low.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.3.3 Major equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
Index Indicates the alarm index.
EntityPhysicalIndex Indicates the physical entity index.
PhysicalName Indicates the name of the physical entity where the alarm is generated.
EntityTrapEntType Indicates the alarm type.
EntityTrapFaultID Indicates the error code of the alarm.

Impact on the System

The low temperature may affect operation of the lithium battery.

Possible Causes

The discharge temperature range for a lithium battery is -5°C to 50°C. When the discharge temperature of the lithium battery is lower than the lower temperature threshold, the system generates a lower temperature alarm.

Procedure

  • Increase the ambient temperature.