Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 67590

SRM_1.3.6.1.4.1.2011.5.25.129.2.1.9 hwEntityInvalid 67590

Description

SRM/3/ENTITYINVALID:OID [OID] temperature chip exception. (EntityPhysicalIndex[INTEGER1], BaseTrapSeverity=[INTEGER2], BaseTrapProbableCause=[INTEGER3], BaseTrapEventType=[INTEGER4], EntPhysicalContainedIn=[INTEGER5], EntPhysicalName=[OCTET1], RelativeResource=[OCTET2], ReasonDescription=[OCTET3])

This alarm was generated when the chip was detected abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.129.2.1.9 Minor equipmentAlarm(5)

Parameters

Name Meaning
OID OID of the MIB
EntityPhysicalIndex Entity index
BaseTrapSeverity Severity code
BaseTrapProbableCause Error code
BaseTrapEventType Code of the event type
EntPhysicalContainedIn Entity code
EntPhysicalName Entity name
RelativeResource Name of the affected component
ReasonDescription Fault description

Impact on the System

The temperature of the board cannot be obtained. As a result, the fan module cannot automatically adjust the rotational speed according to the temperature of the board. The fan module thus keeps working at the full rotational speed with too much noise. The services, however, are not affected.

Possible Causes

The IIC bus was faulty.

Procedure

  1. Run the display temperature { all | slot slot-id } command to check whether a fault occurs on the temperature sensor due to the faulty IIC bus.

    (1) If the character string "Read Temperature Fail" is displayed in the query result, it indicates that the IIC bus is faulty. In this case, you need to replace the device.

    (2) If the character string "Read Temperature Fail" is not displayed in the query result, it indicates that the fault on the IIC bus is rectified. In this case, you need to go to Step 2.

  2. End.