Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FSP_1.3.6.1.4.1.2011.5.25.183.1.22.59 hwStackPortErrorDown

FSP_1.3.6.1.4.1.2011.5.25.183.1.22.59 hwStackPortErrorDown

Description

FSP/3/PORTERRDOWN: OID [OID] STACK port [STRING] trigger error down. Error down type: [STRING].

An error-down event occurred on a stack port.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.183.1.22.59 Minor communicationsAlarm (2)

Parameters

Name Meaning
OID Indicates the ID of a MIB object.
STACK port Indicates the local port name.
Error down type Indicates the error-down event type.

Impact on the System

The stack may split because the port is unavailable.

Possible Causes

Cause 1: The stack port receives CRC and Runts error packets.

Cause 2: The stack port frequently alternates between Up and Down states.

Procedure

  1. Run the display stack port brief command to check the stack port error-down reason.

    • If the reason is Link-flapping trigger error down, rectify the fault according to An Ethernet Interface Frequently Alternates Between Up and Down States.

    • If the reason is CRC trigger error down or Runts trigger error down, go to step 2.

  2. Replace the optical module and run the display interface interface-type interface-number command to check whether the number of CRC error packets received by the interface keeps increasing.

    • If so, go to step 3.

    • If not, the alarm handling ends.

  3. Replace the fiber and run the display interface interface-type interface-number command to check whether the number of CRC error packets received by the interface keeps increasing.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.

    • If not, the alarm handling ends.