Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DHCP_1.3.6.1.4.1.2011.5.25.112.2.16 hwNdSnpUserNumberAlarmGlobal

DHCP_1.3.6.1.4.1.2011.5.25.112.2.16 hwNdSnpUserNumberAlarmGlobal

Description

DHCP/4/NDUSERBINDTRAPGLOBAL:OID [OID] The number of ND global users exceeds alarm threshold. (IfIndex=[INTEGER], VlanIndex=[INTEGER], CurrentUser=[INTEGER], MaxUser=[INTEGER])

The number of global ND users reaches the upper alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.112.2.16 Warning equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

IfIndex

Indicates the interface index. The value is 0.

VlanIndex

Indicates the VLAN index. The value is 0.

CurrentUser

Indicates the number of current access users.

MaxUser

Indicates the maximum number of access users.

Impact on the System

None.

Possible Causes

The number of global ND snooping binding entries reaches the upper alarm threshold.

Procedure

  1. Run the nd snooping max-user-number max-user-number command to adjust the maximum number of ND snooping binding entries that can be learned by an interface.
  2. Run the nd snooping user-alarm percentage percent-lower-value percent-upper-value command to configure the alarm thresholds for ND snooping binding entries.

Related Information

None.