No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S600-E V200R010C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
IFNET_1.3.6.1.4.1.2011.5.25.41.4.2 hwIfMonitorCrcErrorResume

IFNET_1.3.6.1.4.1.2011.5.25.41.4.2 hwIfMonitorCrcErrorResume

Description

IFNET/1/CRCERRORRESUME: OID [oid] The CRC error resume. (hwIfMonitorIndex=[INTEGER], hwIfMonitorCrcErrorStatistics=[COUNTER64], hwIfMonitorCrcErrorThreshold=[INTEGER], hwIfMonitorCrcErrorInterval=[INTEGER], InterfaceName=[STRING])

The trap is cleared if the number of CRC errors is smaller than the specified value in the specified time.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.41.4.2 Critical other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

hwIfMonitorIndex

Indicates the interface index.

hwIfMonitorCrcErrorStatistics

Indicates statistics on CRC errors.

hwIfMonitorCrcErrorThreshold

Indicates the threshold for CRC trap (a trap is generated if the number of CRCs exceeds the threshold).

hwIfMonitorCrcErrorInterval

indicates the time period for collecting CRC error statistics.

InterfaceName

indicates the interface name.

Impact on the System

Services will be restored.

Possible Causes

The trap that the number of packets that are dropped because they failed the CRC exceeded the threshold was cleared.

Procedure

  1. This alarm message is informational only, and no action is required.